Página 1 - Operator's Manual

14-DIN SETPOINT PROGRAMMEROperator's Manual59215-1PROG

Página 2

2.5 VIEWING PROGRAM AND CONTROLLER PARAMETERSIn Base Mode (i.e. with no program currently running or held), the MODE key gives “viewonly” access to Pr

Página 3 - Con tents

3 PROGRAMS3.1 SELECTING AND RUNNING A PROGRAMWhen no program is running, the Setpoint Programmer is in Base Mode and the RUN andHLD indicators are OF

Página 4 - (iv ) 59215-FM

3.5 VIEWING PROGRAM PROGRESS/STATUSIn Program Run Mode, a number of displays are made available to the operator (in theMessage Display area) which ind

Página 5 - 59215-1 Page 1-1

3.6 ABORTING A PROGRAMThe operator may abort (i.e. terminate) the current program by holding down the Run/Holdkey for more than five seconds. When the

Página 6 - 2 Entry via a Lock Code

4 ADJUSTING THE SETPOINTWith the Setpoint Programmer in Base Mode (i.e. with the RUN , HLD , SET and PRGindicators OFF), the two main displays will s

Página 7 - 2.1 CONTROLS

5 USING THE SELF-TUNE FACILITYThe Self-Tune facility is used to optimise tuning whilst the Controller part of the SetpointProgrammer is operating. Sel

Página 8 - 2.2 INDICATORS

6 USING THE PRE-TUNE FACILITYThe Pre-Tune facility is used to set the Setpoint Programmer’s PID control parameters tovalues which are approximately co

Página 9 - 2.4 ALARM STATUS INDICATION

7 MANUAL CONTROLIn any mode except Configuration Mode or Calibration Mode, the operator may selectmanual control of the process by simultaneously pres

Página 10 - Page 2-4 59215-2

8 DEFINING AND VIEWING A PROGRAM (PROGRAM DEFINE MODE)The Setpoint Programmer may be put into Program Define Mode from either Base Mode or Program Ru

Página 11 - 3 PROGRAMS

8.2 PARAMETERS COMMON TO ALL PROGRAMS (GLOBAL)Parameter MessageDisplayFunction Available Settings(Lower Main Display)Start On Setpoint value at start

Página 12 - Page 3-2 59215-3

PREFACEThis manual is intended for use in support of day-to-day operation of the 14-DIN Setpoint Programmer. For information on installation,commissio

Página 13 - 3.6 ABORTING A PROGRAM

8.3 PARAMETERS WHICH APPLY TO A SPECIFIC PROGRAM AS AWHOLEParameter MessageDisplayFunction Available Settings(Lower Main Display)Cycle Count Defines t

Página 14 - 4 ADJUSTING THE SETPOINT

59215-8 Page 8-459215Fig ure 8-1 Auto Hold Op era tion

Página 15 - 59215-5 Page 5-1

8.4 PARAMETERS IN ANY/EACH SEGMENT IN A SPECIFICPROGRAMParameter MessageDisplayFunction Available Settings(Lower Main Display)Final SetpointValueDefin

Página 16 - 6 USING THE PRE-TUNE FACILITY

CANCELLING JOIN, REPEAT OR END MARKERSTo cancel a Join, Repeat or End Marker:(a) at the Fi nal Set point Value pa rame ter, press the Up and Down keys

Página 17 - 7 MANUAL CONTROL

There are no restrictions on joining programs; several programs can be joined to oneprogram (e.g. to provide user-selectable warm-up programs, dependi

Página 18 - (PROGRAM DEFINE MODE)

At the end of the tenth cycle of Program 2, the program sequence would end.8.6 BASIC RULES TO REMEMBERIn any program sequence:*A pro gram end ing in a

Página 19

9 DEFINING THE CONTROLLER PARAMETERS (CONTROLLER DEFINE MODE)Entry can be made into this mode from Program Define Mode, Program Run Mode or BaseMode.T

Página 20

9.1 CONTROLLER PARAMETERSThe Controller parameters appear in the following sequence:Parameter MessageDisplayFunction Available Settings/Values(Lower M

Página 21 - 59215-8 Page 8-4

Parameter MessageDisplayFunction Available Settings/Values(Lower Main Display)Setpoint LowLimit6The minimum limit for setpointadjustment. Should be se

Página 22

Parameter MessageDisplayFunction Available Settings/Values(Lower Main Display)Deviation(High/Low) Alarm 1 valueIf Alarm 1 is a Deviation(High/Low) Ala

Página 23 - PROGRAMS

Con tents1 IN TRO DUC ING THE SET POINT PRO GRAM MER 1-12 FRONT PANEL CON TROLS, IN DI CA TORS & DIS PLAYS 2-12.1 CON TROLS ...

Página 24 - Page 8-7 59215-8

Parameter MessageDisplayFunction Available Settings/Values(Lower Main Display)Loop Alarm Time If ON/OFF control is selected(i.e PB1 = 0) and Loop Alar

Página 25 - 8.6 BASIC RULES TO REMEMBER

NOTES ON CONTROLLER DEFINE MODE PARAMETERS (Cont.)6. Internal software prevents (a) the Setpoint High Limit being given a value less than any setpoin

Página 26 - (CONTROLLER DEFINE MODE)

Page 9-7 59215-959215Fig ure 9-1 Pro por tional Band and Dead band/Over lap

Página 27 - 9.1 CONTROLLER PARAMETERS

59215-9 Page 9-859215Fig ure 9-2 Alarm Operation

Página 28

Page 9-9 59215-959215Fig ure 9-3 Alarm Hys tere sis Operation

Página 29

9.2 BASE MODE DISPLAYSOnce the complete cycle of Controller Define Mode parameters has been displayed, theuser may then step through the Base Mode dis

Página 30

9.4 EXITING CONTROLLER DEFINE MODEThe operator may exit from Controller Define Mode by pressing the MODE key until theExit ? prompt appears in the Me

Página 31

Al pha betic In dexAAborted ProgramIndication of 3-3Alarm StatusDisplay of 2-3, 3-2ALM IndicatorFunction 2-2AT IndicatorFunction 2-2Auto-HoldIndicat

Página 32 - Page 9-7 59215-9

Mode IndicatorsFunctions 2-2NNext SegmentJump to 3-1Number of Cycles CompletedDisplay of 3-2OOP1 IndicatorFunction 2-2OP2 IndicatorFunction 2-2PPre-Tu

Página 33 - Fig ure 9-2 Alarm Operation

9 DE FIN ING THE CON TROL LER PA RAME TERS (CON TROL LER DE FINE MODE) 9-19.1 CON TROL LER PA RAME TERS ...9-29.2 BASE MODE DIS P

Página 34 - Page 9-9 59215-9

1 INTRODUCING THE SETPOINT PROGRAMMERThe Setpoint Programmer is a powerful, easy-to-use 14-DIN instrument with full PID control capability (complete w

Página 35 - 9.2 BASE MODE DISPLAYS

The Setpoint Programmer has four operating modes:Base Mode: Day-to-day PID control operations with no programrunning. In this mode, a program may be s

Página 36 - Page 9-11 59215-9

2 FRONT PANEL CONTROLS, INDICATORS & DISPLAYS2.1 CONTROLS59215-2 Page 2-159215MODE key: Changes mode of instrument.PROG key: Cycles through Progra

Página 37 - 59215-IDX 1

2.2 INDICATORSPage 2-2 59215-259215Event IndicatorsEach indicates the status (active or inactive) of auser-defined event (OFF = inactive, ON = active)

Página 38 - 2 59215-IDX

2.3 D ISPLAYS2.4 ALARM STATUS INDICATIONWhen any alarm is active, the ALM indicator will flash. To view the alarm status in theMessage Display, press